Storefront Clearance – Use Hilti EZ-P – JEI Glazing Engineer Recap

When using the Hilti KwikHUS EZ you can now use the EZ-P under the same design per Hilti’s latest data, good example of always looking at the latest info on a product when using it. The EZ-P used to be metric only and required a separate design to use the shallow pan head instead of the HWH. Good change for storefront that needs the clearance. Hilti KwikHUS EZ or EZ-P Storefront Screw Options - JEI Structural Engineering ReCap May 2020

Hilti also has the EZ E that has a threaded rod stud on it that might be useful in some cases.

Hilti Threaded Screw for Storefront - Recap by JEI Structural Engineering May 2020.jpg

These have all be incorporated into the ICC report for quite a while.  Always a good idea for engineers or project managers to quickly check the ICC report on each project to be aware of any pertinent changes.

Need Curtain Wall Engineering or Facade Design

For more help from engineers focused solely on glass & glazing installation, contact:

Email construction documents to:

JEI Structural Engineering